When we install the tanker, what problems do we need to pay attention to? These points need to be kept in mind, let's learn about it with the small tanker manufacturer:
Xost o'rnatish
1. The horizontal distance between the main engine and the underground oil tank is generally not more than 50 meters, the vertical distance is not more than 5 meters, and the pipe corners should be as few as possible to affect the flow. The installation location should comply with the relevant regulations of GB50516-92 "Code for Design of Small Oil Depots and Automobile Gas Stations" and GBJ16-87 "Code for Fire Protection of Architectural Design".
2. Asosiy dvigatelning asosi tsement poydevoriga o'rnatilishi va ankraj murvatlari bilan o'rnatilishi kerak. Tsement poydevori neft quvurlari, kabellar va topraklama simlarini kiritish uchun teshiklarni qoldirishi kerak. O'rnatishdan so'ng, teshiklarni sariq qum bilan to'ldiring.
3. Körükli ulanish gardish moy kirish trubkasi bilan bog'langan. Flanjlar orasiga qistirma qo'shgandan so'ng, mahkamlash simini torting.
4. Mashina ochiq havoda o'rnatilganda, mashinani yomg'ir va quyoshdan himoya qilish uchun soyabon bo'lishi kerak.
Quvvatni o'rnatish
1. Elektr shnuri yaxshi yog'ga chidamliligi va korroziyaga chidamliligi bo'lgan plastik qoplamali mis yadroli kabeldan (RVV) tayyorlanishi kerak. Supero'tkazuvchilar kesma maydoni 1,5 kvadrat millimetrdan kam emas, kabelning tashqi diametri esa taxminan 8 mm.
2. Elektr ta'minotining asosiy kaliti bino ichida joylashgan bo'lishi kerak va kalit sug'urta quvvati tankerning asosiy quvvat manbai nominal oqimiga qarab aniqlanishi kerak.
3. Foydalanuvchi quvvat liniyasi (uch{1}}fazali sim) va signal kabeli mashinaning portlashdan himoyalangan ulanish qutisiga- ulangan. E'tibor bering, kiruvchi kabelning tashqi diametri portlashdan himoyalangan ulanish qutisining sim kirish teshigidagi rezina qistirmaning ichki teshik o'lchamiga- mos kelishi kerak (taxminan 8 mm). Kabelning ulanish qutisiga-portlashdan himoyalangan ishlashi. Shlangi bilan ishlatiladigan metall qistirma qistirmani himoya qiladi va siqadi va uni yo'qotib bo'lmaydi.
4. Portlashdan himoyalangan ulanish qutisiga ulangan -uch fazali quvvat manbaining fazalar ketma-ketligi to'g'ri bo'lishi kerak. Dvigatelning rulini va moy nasosining kasnagida belgilangan o'qning yo'nalishini izchil qiling. Rulda noto'g'ri bo'lsa, uch fazali liniyalardan ikkitasini almashtiring.
5. Aloqa qutisining bir tomonida topraklama shinasida topraklama vinti mavjud. Iltimos, yerga ulash simini ulang va torting. Ishonchli topraklamani ta'minlash uchun topraklama simini 1 m dan ortiq chuqurlikda er ostiga ko'milishi va sho'r suv bilan sug'orilishi kerak.
6. The explosion-proof junction box used for the interface between the user's power supply system and the local power supply system has 5 outlet holes and 9 connection terminals, of which A, B, and C are connected to the phase line, and N must be connected to the neutral line, otherwise the machine will not work normally.
7. 30D seriyali tankerning markaziy kompyuterining aloqa liniyasi CTXD, CRXD va kengaytirish platasida mos ravishda G12 orqali markaziy kompyuter hubining aviatsiya vilkasi bilan ulangan.
8. Foydalanuvchi quvvat liniyasi (bir{1}}uchinchi fazali-sim) va signal kabeli mashinaning portlashdan himoyalangan ulanish qutisiga- ulangan.